Environmental Requirements:
Control Unit |
- Mount the PARTNER communications system on a wall at least 2 feet
(0.6) meters from the floor (wall mounting required)
- Locate the PARTNER communications system within 5 feet (1.5 meters)
on the network interface jacks and a properly grounded electrical outlet
not controlled by a switch, using supplied 7-foot (2.1 meter) cords.
- Operating temperature 32° to + 104°F (0° to + 40°C), not in direct
sunlight
- Humidity 15%-90%, noncondensing
- For proper ventilation and easy replacement of modules, provide the
following minimum clearance around the control unit:
- 5-slot carrier: 1 foot (0.3 meter) clearance at the top
and sides and 2 feet (0.6 meter) at the front and bottom
- 2-slot carrier: 1 foot (0.3 meter) clearance at the front,
top and right sides, and 2 feet (0.6 meter) at the bottom and left
side
- Locate in an area free of excess moisture, corrosive gases, dust,
and chemicals
|
Electrical Requirements:
Control Unit
|
- U.S. and Canada: 90-264 VAC, 47-63 Hz, 3-prong outlet separate ground,
separately fused at 15 Amps
- Other countries: 90-264 VAC (220 VAC fused at 10 Amps)
- Grounding to comply with Underwriters Laboratories (UL) 1459:
- An insulated grounding conductor that is not smaller in size and
equivalent in insulation material and thickness to the grounded
and ungrounded branch circuit supply conductors, except that is
green with or without one or more yellow stripes, is to be installed
as part of the circuit that supplies the product or System
- The grounding conductor mentioned above is to be connected to
ground at the service equipment
- The attachment-plug receptacles in the vicinity of the product
or System are all to be of a grounding type, and the grounding conductors
serving these receptacles are to be connected to earth ground at
the service equipment
|