Sets the minimum number of measurements required by the Decision Maker process before a prefix can be considered sufficiently measured to be a candidate for updating.
min-required-measurement <value> no min-required-measurement
Must be in engine configuration mode (config-engine), which requires privileged-level access.
The value you set establishes a minimum number of traffic test measurements required before CNA will determine a best path for a prefix.
If too many prefixes are labeled I (insufficient data) when you execute the show prefix command, decrease the min-required-measurements value. This will allow CNA to make more best-path determinations.
Because of the way the CNA software calculates the HRTT value that is stored in the database, a very low minimum measurement value could incorrectly give too much influence to the first few measurements. Avaya recommends you set this value no lower than 4, except in test or demonstration environments.
The no form of the command resets the minimum to its default value.
|
|
|