clear statistics
Clears CNA counters for statistics which are visible in various show command output displays.
clear statistics <process> [ <number> | all ] [ avoid | diagnose ]
- process--name of the internal process; can be one of:
- am-scheduler--active-measurement process on the engine module
- am-measurer--active-measurement process on a USTAT module
- dmaker--decision-maker process on the engine module
- dm-listener--decision-maker listener process on the engine module
- edgestats--user-traffic-test process on a USTAT module
- event-manager--Event Manager process on the management module
- link-monitor--SNMP polling process
- logging--logging process on any module
- monitor--monitor (SPAN listener) process on the EFC module
- number--slot or subsystem number for which statistics are to be cleared
System operations mode, privileged-level access.
The clear statistics command resets counters to 0 for statistics maintained by various CNA processes.
The keyword diagnose is valid only for the am-measurer and am-scheduler processes. Use it to clear all diagnostic statistics.
The keyword avoid is valid only for the am-measurer process. Use it to clear all entries in the probe avoidance table.