Previous page Next page

EFC Module Configuration

If you will be listening for Netflow data, enter config-efc mode and add the IP address of the router interface from which Netflow data will be received and the UDP port number to which the router is sending the Netflow packets:

Avaya_ANS(config)# module efc
 
Avaya_ANS(config-efc)# netflow source 192.168.1.15
 
Avaya_ANS(config-efc)# netflow port 9995
 
Avaya_ANS(config-efc)# end
 

NOTE: The port configured on the EFC module must match the port assignment configured on the router. All routers sending Netflow data to the CNA system should use the same UDP port number. You can specify multiple Netflow router IP addresses but only one Netflow UDP port in the CNA configuration.

Other than monitor enable, there are no configuration commands needed on the EFC module to listen for SPAN data.