- Start at the Administration
main menu and select:
Diagnostics
Voice Equipment Diagnostics
Diagnose
The system displays the
Diagnose Equipment page.
- Complete the fields on the page. For more information, click the field names or
Help on the web-based administration page.

Do not diagnose all of the analog-line interface cards or
channels at once. This kind of diagnosis can leave no channels
available on the system to accept incoming calls.
|
- Click Diagnose.
Depending on the equipment
selected, diagnosis can take several minutes. The System displays
the Voice Board Diagnostics results page
as the system performs the diagnosis.
- If the system displays either of the following
messages, the system did not detect a working telephone line connected
to the voice port. If you see either of the following messages complete
Step a through Step c.
No loop current
on channel
number
Channel number
changed to state FOOS
- Verify that the telephone
line is properly connected to both the interface card and the switch.
- Verify that the analog
line is set up properly on the switch.
- Verify that the switch
port has a dial tone. To do so, remove the analog line, plug in
an analog telephone, and listen with the handset for dial tone.
If there is a dial
tone, the analog-line interface card is defective. If there is no
dial tone, the problem is with the switch. Verify the wiring and
administration of the switch.
If the system displays
the following message, the system did not detect a dial tone. However,
it did detect loop current, which could be a result of excessive
load on the analog-line interface card. If you see the following
message, complete Steps d and e.
Diag TR
number
:
No dial tone frequencies set
- Verify that the analog
lines are distributed over several analog-line interface cards.
- Verify that the switch
administration for the ports is valid.
If the system displays
either of the following messages, the channel or card is not working
and you must replace the analog-line interface
card:
Channel number
changed to state BROKEN
Card number changed
to state BROKEN
- If the card is NONEX (nonexistent), follow the procedures to get
inside the PC and verify that the card is properly seated in the
slot. If the card is not properly seated, correct the seating of the
card and then follow the procedures to return
power and replace the PC cover.
- Click Return to Main.