AS (Access Security
Gateway) Alarm
|
The following alarm is generated by the AS application and indicates
a problem with the Access Security Gateway (ASG):
AS ASG 2
Description:
Someone tried, and failed, to log in
to the INTUITY AUDIX LX system using an ASG-protected login.
Repair Procedure:
- Identify the employee who is using the failing login ID. Verify if
the employee assigned to work on the system has been having difficulty
logging in or needs additional training.
- Test the login. See How to Log In with
ASG. If the login fails the key might be having problems or the
initial code might have been entered incorrectly. Do the following:
- Re-administer the key. See Changing
the ASG Secret Key Number for an ASG Login. The login making
the change must be equal to or higher than the login being changed.
For example, the sa login can change both the sa and vm logins,
but the vm login can only change the vm login.
- Test the login after changing the ASG secrect key. See How
to Log In with ASG. If the
login continues to fail, contact your remote support center.
|