Converting 4602+/4610SW/4620SW/4621SW IP Telephones

An H.323 IP telephone can be either in use with possible customized settings or out of the box with factory default settings. An out of the box telephone requires accessing the manual programming mode early in the process and setting the Signaling Protocol Identifier (SIG) parameter to “SIP.” Converting to SIP early avoids having to first load H.323 software, log in, and then invoke the “in use” process to load the SIP software.

NOTE: For information about the SIG parameter, see “Choosing the Right Application File and Upgrade Script File” in the 4600 Series IP Telephone LAN Administrator Guide (Document Number 555-233-507). For information on setting or changing the SIG parameter, see Signaling Protocol Identifier.

Table 1:  H.323 to SIP and SIP to H.323 Conversion Chart 

Environment
To convert this type of telephone
To this type of telephone

Then:
H.323-centric
H.323 in use
SIP
Perform the Mute SIG procedure to change the SIG parameter value from “default” to “2" (SIP).” For information, see Signaling Protocol Identifier.
Press * to save the SIG parameter change. Restart the telephone as covered in Restart the Telephone.
H.323-centric
H.323 factory set
SIP
Connect the telephone to a power source and to the network.
As soon as you see the DHCP prompt, press * to enter manual programming mode. Press # multiple times to accept the existing values until the telephone displays “Enter command.”.
Perform the Mute SIG procedure and change the value from “default” to “2" (SIP).
Press * to save the SIG parameter change. Restart the telephone as covered in Restart the Telephone.
H.323-centric
SIP
H.323
Perform the Mute SIG procedure to change the SIG parameter value from “2" (SIP) to “default” (H323). For information, see Signaling Protocol Identifier.
Press * to save the SIG parameter change. Restart the telephone as covered in Restart the Telephone.
Save the change & restart telephone.
SIP-centric
SIP
H.323
Perform the Mute SIG procedure to change the SIG parameter value from “default” to “1" (H323). For information, see Signaling Protocol Identifier.
Press * to save the SIG parameter change. Restart the telephone as covered in Restart the Telephone.
SIP-centric
H.323 in use
SIP
Perform the Mute SIG procedure to change the SIG parameter value from “1" (H323) to “default” (SIP). For information, see Signaling Protocol Identifier.
Press * to save the SIG parameter change. Restart the telephone as covered in Restart the Telephone.
SIP-centric
H.323 factory set
SIP
No action is required because the Signaling Protocol Identifier (SIG) defaults to SIP. Upon power-up & network connection, the telephone automatically downloads the proper SIP files from SES/CM.