Avaya Logo

Previous Topic

Next Topic

Book Contents

Book Index

Change Loop Start T1 parameters screen

Use this screen to configure the Loop Start T1 protocol for the card.

Field descriptions

Field

Description

Frame Type

The frame format.

Values: D4, ESF.

Line Code

The replacement for strings of consecutive zeros in data transmission using pulse code modulation (PCM).

Values: AMI, AMI_ZCS, B8ZS.

Idle Code

The code used in digital communications that represents an absence of data.

Values: 11111111, 01010100, 01010101.

Note: If channels are not recognized as off-hook even though the voice system has stopped, change the Idle Code to 11111111. This is a known issue with DS1 connectivity to MultiVantage S8300.

Length

The length of the cable in feet between the telephony board and the telephone network.

Values: 0-655.

This value is an integer. It should only be changed if the length is more than 200 feet or if there are transmission problems.

Clock Trunk

The trunk that the board uses for its internal clock reference.

Values: 1, 2 (for dual port cards); 1, 2, 3, 4 (for quad port cards).

Clock Source

The origin of the board's clock reference.

Values: NETWORK, OSCILLATOR.

NETWORK refers to the clock extracted from the trunk, OSCILLATOR refers to the board's oscillator.

Clock Mode

The control of the board's clock.

Values: STANDALONE.

The board controls its own clock.

Clock Fallback Trunk

The trunk that the system uses to set its internal clock if the timing source on the Clock Trunk stops working.

Values: none, 1, 2 (for dual port cards); none, 1, 2, 3, 4 (for quad port cards).

Fax Enabled?

The availability of fax with the protocol.

Values: yes, no

Country and Region

The country or region in which the Avaya IR system is located.

Values: Hong Kong, Japan, United States.

Enabled Channels

The number of channels that have been enabled.

Values: 0-128

Button descriptions

Button

Description

Submit

Assigns the card to the protocol and prompts the user to stop and restart the voice system

Reset

Sets fields to their default values

Cancel

Displays the Change parameters screen

Help

Displays the system help files

Administration procedures