Use this screen to change the R2 MFC E1 protocol parameters.
Field descriptions
Field |
Description |
Frame Type |
The frame format. Values: CEPT. |
Line Code |
The replacement for strings of consecutive zeros in data transmission using pulse code modulation (PCM). Values: HDB3. |
Idle Code |
The code used in digital communications that represents an absence of data. Values: 11111111, 01010100, 01010101. |
CRC |
Cyclical Redundancy Checking (CRC) is an error checking technique that is used to ensure the accuracy of digital transmissions over a communications link. To enable CRC for one or more E1 trunks, select the check boxes for the appropriate E1 trunks. |
Clock Trunk |
The trunk that the board uses for its internal clock reference. Values: 1, 2 (for dual port cards); 1, 2, 3, 4 (for quad port cards). |
Clock Source |
The origin of the board's clock reference. Values: NETWORK, OSCILLATOR NETWORK refers to the clock extracted from the trunk, OSCILLATOR refers to the board's oscillator. |
Clock Mode |
The control of the board's clock. Values: STANDALONE. The board controls its own clock. |
Clock Fallback Trunk |
The trunk that the system uses to set its internal clock if the timing source on the Clock Trunk stops working. Values: none, 1, 2 (for dual port cards); none, 1, 2, 3, 4 (for quad port cards). |
Fax Enabled? |
The availability of fax with the protocol. Values: yes, no. |
Country |
The country that the system is in. Values: Argentina, Brazil, Chile, China, Colombia Telecom, Colombia ComSel, India, Indonesia, Korea, Malaysia, Mexico, Philippines, Singapore, Thailand. |
Number of DID digits |
The number of allowable DID digits. Values: 1-30. |
Number of ANI digits |
The number of allowable ANI digits. Values: 0-30. |
Collect Call Block Method |
The method the system uses to block incoming collect calls. The Collect Call Blocking Method field is available only if the Country field is set to Brazil. Values: none (default), Double Answer, Group II signal 8. |
Wink Delay |
The amount of time (in milliseconds) from when the incoming call was answered until the start of the wink (hang up or on-hook). The Wink Delay field is available only if the Collect Call Block Method field is set to Double Answer. Values: 500-1500. The default value is 1000. |
Wink Duration |
The duration of the wink (in milliseconds). The Wink Duration field is available only if the Collect Call Block Method field is set to Double Answer. Values: 500-2500. The default value is 2000. |
Enabled Channels |
The number of channels that have been enabled. Values: 0-128 |
Button descriptions
Button |
Description |
Submit |
Assigns the card to the protocol and prompts the user to stop and restart the voice system |
Reset |
Sets fields to their default values |
Cancel |
Displays the Change parameters screen |
Help |
Displays the system help files |
Administration procedures