more topics

Touch-Tone or Rotary Signaling Feature

System Programming

Outmode Signaling for Loop- or
Ground-Start Trunks
 

Programmable by

System Manager

Mode

Loop-Start: All; Ground-Start: Hybrid/PBX only

Idle Condition

Not required

Planning Form

2c, System Numbering: Line/Trunk Jacks

Factory Setting

Touch-Tone

Valid Entries Touch-Tone, Rotary
Inspect No
Copy Option

Yes

Procedure

Program a single line/trunk:

LinesTrunksTT/LS DiscOutmode
Select entry mode (Touch-Tone or rotary)Dial no. of line/trunkEnter or DeleteBackBackBack

Program a block of lines/trunks:

LinesTrunksTT/LS DiscOutMode
Select block of lines/trunksToggle LED On/Off
Enter or DeleteBackBackBack

Dial Mode for Tie Trunks  

Programmable by

System Manager

Mode

All

Idle Condition

Not required

Planning Form

3c, Incoming Trunks: Tie

Factory Setting

Rotary

Valid Entries Rotary, Touch-Tone
Inspect Yes
Copy Option

Yes

Procedure

To program a single tie line:

LinesTrunksTIE LinesInmode or Outmode
Entry Mode
Dial line/trunk no.Enter or DeleteBackBackBack

To program a block of tie lines:

LinesTrunksTIE LinesInmode or Outmode
Select block of linesToggle LED On/OffBack
Back
Back

DID Signaling  

Programmable by

System Manager

Mode

Hybrid/PBX

Idle Condition

Not required

Planning Form

3d, Incoming Trunks: DID

Factory Setting

Rotary

Valid Entries Rotary, Touch-Tone
Inspect No
Copy Option

No

Procedure

Change DID trunk block to rotary or Touch-Tone signaling:

LinesTrunksDIDSignalingDial trunk block no.EnterRotary or TouchToneEnterBackBack

Rotary Trunk Digit Transfer  

Programmable by

System Manager

Mode

All

Idle Condition

Not required

Planning Form

8a, System Features

Factory Setting

No Delay

Valid Entries Delay, No Delay
Inspect No
Copy Option

No

Procedure

Change rotary signaling:

Optionsor MoreRotarySelect option (Delay or No Delay)EnterBack

Rotary Signaling on Tip/Ring Ports  

Programmable by

System Manager

Mode

All

Idle Condition

System idle

Planning Form

4f, Tip/Ring Equipment

Factory Setting

Touch-Tone

Valid Entries Extension numbers for rotary dial telephones
Inspect Yes
Copy Option

No

Procedure

Enable rotary signaling:

Extensionsor Moreor MoreRotaryEnabl
Type rotary ext. no.EnterBackBack

To disable rotary signaling, you must delete the extensions you entered.

Topics
  Description
 
  Touch-Tone Receiver (TTR)
System Requirements for TTRs Table
TTRs Required by Voice Messaging Systems/Auto Attendants Table
TTRs Required for Primary Delay Announcement Devices When Using Prompt-Based Overflow Table
TTRs Required for Secondary Delay Announcement Devices When Using Prompt-Based Overflow Table
Steps to Calculate Required TTRs
TTR Settings
  At a Glance
  Considerations & Constraints
  System Programming
  Mode Differences