Users Affected |
Telephone users, operators, digital data users |
Reports Affected |
System Information (SysSet-up), BRI Information |
Modes |
Key, Hybrid/PBX |
Telephones |
All |
System Programming |
Assign telephone numbers (SPID and DN) to BRI lines:
Specify BRI timer settings:
|
Maximums |
|
Factory Settings System-wide ClockSynchronization Source Primary Clock Clock |
Loop (not definable by System Manager) First port in service on an 800 NI-BRI module, or first 100D module in service in control unit Active |
BRI Service Profile Identifier (SPID) assigned to BRI line Directory Number (DN) assigned to BRI line |
0 digits 0 digits |
Timer
and counter thresholds for all BRI ports in system T200 Timer T203 Timer T303 Timer T305 Timer T308 Timer |
1,000 ms (range 500-5,000 ms, increments of 500 ms) 33 seconds (range 10-255 seconds, increments of 1 second) 4 seconds (range 2-10, increments of 1 second) 30 seconds (range 2-60, increments of 1 second) 4 seconds (range 2-10, increments of 1 second) |