Made Easy Tool for DEFINITY Media Server Configurations
Issue 5, October 2002
Install and Administer Trunks
Upgrading from a TN722 to a TN767C
- Remove all TN722 trunk members from affected trunk groups.
- Type remove ds1 UUCSS (the slot containing the TN722).
- Remove the TN722 circuit pack.
- Put the TN767C circuit pack into the same slot.
- Wait until the red LED goes off. The hardware tests take 12 to 20 seconds to run. When the red LED goes off, the tests have completed.
- If the red LED stays on, reseat the board and repeat this step.
- Type add ds1 PCSS.
- Continue with appropriate procedures to set up members of trunk groups.
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |