Made Easy Tool for DEFINITY Media Server Configurations
Issue 4, May 2002
Release 9si/10si to Avaya MultiVantage
Verify system status
- Type status system 1 and press Return.
- If there are alarms, take the necessary corrective actions ( display alarms).
- Type display errors and press Return.
- Examine the Hardware Error Log and record any Error Code 18 alarm that identifies existing busyouts. After the upgrade you will restore the busyouts as they were (Restore busyouts).
- For configurations with existing BX.25 links that are being retained after the upgrade, type display communication-interface links and press Return.
- Identify and note all of these links.
- Execute the following commands to see whether the switch has administration:
Check these fields for the corresponding values:
| Copyright� 2002 Avaya Inc. |
| Send comments to MadeEasy Development Team |
| Always check at the Made Easy Web site for the most current information. |