S8300 LED Indicators

On the faceplate of the S8300 Media Server is a set of LED indicators that are separate from those of the G700 Media Gateway. Also on the faceplate is a button that when depressed for two seonds, will shut down the system, including the operating software on the S8300 Media Server. The LED flashes when shutdown is in progress and remains on when it is safe to remove the S8300 Media Server or to power down.

The functions of the other LEDs are:

When the S8300 is a local survivable backup (LSP), no LEDs will be lit during normal operations. In case of a network failure or loss of contact with the primary S8300 (or S8700), the G700 Media Gateway will register with the LSP. At that time, the red Alarm LED will light.

When you first power up the S8300, the red Major Alarm LED will be lit. During startup, an LED test will run, after which all LEDs will be off. At this point, you can connect to the S8300. There will be another flash of LEDs when MultiVantage software starts.