Complete the Upgrade Process (Only When S8300 is Primary Controller)�
Check Media Modules
Begin _____________________
- Type list configuration all and press Enter.
- Verify that the software is communicating with all media modules and that all media modules are listed in the reports.
- Make test telephone calls to verify that MultiVantage Software is working.
Enable Scheduled Maintenance
Begin _____________________
- Type change system-parameters maintenance and press Enter.
- Ensure that the Start Time and Stop Time fields' administration is the same as before the upgrade.
Enable TTI
Begin _____________________
Note: Perform this step only if you disabled TTI before the upgrade.
- Type change system-parameters features and press Enter to change the TTI field back to its value before the upgrade.
- Go to the second page and set the Terminal Translation Initialization (TTI) Enabled? field to y and press Enter.
Check TTI Status
Begin _____________________
- Type status tti and press Enter.
- Check the Percent Complete field.
If the value is 100, then go on to the next section.
If the value is less than 100, repeat Steps 1 and 2 until the Percent Complete field is 100.
Busy Out Trunks
Begin _____________________
- Busy out trunks that were busied out before the upgrade (see Record All Busyouts).
Resolve Alarms
Begin _____________________
- Click View Current Alarms to examine the alarm log.
- Resolve new alarms since the upgrade through the MultiVantage Software using the appropriate maintenance book.
Check for Translation Corruption
Begin _____________________
- Type newterm and press Enter.
If you do not get a login prompt and see the following message:
Warning: Translation corruption detected
follow the normal escalation procedure for translation corruption before continuing the upgrade.
Back up the System
Begin _____________________
- Back up the system as you did before the upgrade.