Translation Update Test (#146)

The Translation Update Test sends the circuit-pack-level information specified by System Administration to the DS1-MM Interface Media Module. Translation includes the following data administered for a DS1-MM Interface Media Module (see output of display ds1 GGGVS command): DS1 Link Length between two DS1 endpoints, Synchronization Source Control, All Zero Suppression, Framing Mode, Signaling Mode, Time Slot Number of 697-Hz Tone, Time Slot Number of 700-Hz Tone, etc.

Table 73. TEST #146 Translation Update Test �
Error Code
Test Result
Description/ Recommendation
ABORT
Internal system error
Retry the command at 1-minute interval s a maximum of 5 times.
FAIL
Internal system software error.
Enter the display ds1 GGGVS command to verify the DS!-MM Interface Media Module translation.
PASS
Translation data has been downloaded to the DS1-M Interface Media Module successfully.
Any
NO BOARD
The test could not relate the internal ID to the port (no board). This could be due to incorrect translations, no board is inserted, an incorrect board is inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the add ds1 GGGVS command to administer the DS1-MM interface if it is not already administered.
If the board was already administered correctly, check the error log to determine whether the board is hyperactive. If this is the case, the board is shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then issue the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.