Previous page Next page

Control Channel Looparound Test (#52)

This test queries the Media Module for its vintage to verify communication with the board.

Table 78. TEST #52 Control Channel Looparound Test
Error Code
Test Result
Description/ Recommendation
None 2100
ABORT
System resources required for this test are not available.
Retry the command at 1-minute intervals a maximum of 5 times.

FAIL
The Media Module failed to return the Media Module code or vintage.
Retry the command a maximum of 5 times.
If the problem continues, replace the Media Module.
Retry the command.

PASS
Communication with this Media Module is successful.
0
NO BOARD
The test could not relate the internal ID to the port (no board). This could be due to incorrect translations, no board is inserted, an incorrect board is inserted, or an insane board is inserted.
If the board was found to be correctly inserted in step 1, then issue the busyout board GGGVS command.
Issue the reset board GGGVS command.
Issue the release board GGGVS command.
Issue the test board GGGVS long command.
This should re-establish the linkage between the internal ID and the port.


Previous page Next page