Table 46. 8-Port Analog Line Error Log Entries
Error Type
Aux Data
Associated Test
Alarm Level
On/Off Board
Test to Clear Value
0*
0
Any
Any
Any
test port GGGVSpp sh r 1
15 (a)
Any
Audits and Updates Test (#36)



18
0
busy-out station extension
WARNING
OFF
release station extension
130 (b)

None
WARNING
ON
test port GGGVSpp sh
769

Battery Feed Test (#35)
MINOR
ON
test port GGGVSpp sh r 2
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test description and follow the recommended procedures
Notes:
(a) This is a software audit error that does not indicate any hardware malfunction. Run Short Test SeSquence and investigate errors.
(b) Indicates that the Media Module has been removed or has been insane for more than 11-minutes. To clear the error, reseat or replace the Media Module.