Previous page Next page

Station Status and Translation Audits and Updates Test (#36)

For an analog line port that is administered as an external alarm, this test is limited to updating the software with the switchhook state.

Table 49. TEST #36 Station Status and Translation Audits and Updates �
Error Code
Test Result
Description/Recommendation

ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
1004
ABORT
The port received an EXT-DEV failure during the test. The test has been aborted.
Enter test external-device-alarm port GGGVSpp to determine if the port is reporting an EXT-DEV failure before retesting.
If the port has no EXT-DEV failure, retry the command at 1-minute intervals for a maximum of 5 times.
1006
ABORT
This port has been busied out by command.
Check Error Log for Error Type 18 (port busied out). If present, release the port with the release port command and run the test again.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
1
FAIL
This failure does not indicate a hardware problem. The switchhook audit failed, this condition may occur when the audit is performed at the same time that the terminal equipment goes off-hook.
Enter test external-device-alarm port GGGVSpp to determine if the port is reporting an EXT-DEV failure before retesting. Wait until the port has no EXT-DEV failure before retesting
If the port has no EXT-DEV failure, retry the command at 1-minute intervals for a maximum of 5 times.
7
FAIL
The translation update failed. This does not indicate a hardware problem but may be an internal software error.

PASS
The software and the port processor have the same status.