Previous page Next page

Error Log Entries and Test to Clear Values

Table 51. Analog Line Error Log Entries�
Error Type
Aux Data
Associated Test
Alarm Level
On/Off Board
Test to Clear Value
0*
0
Any
Any
Any
test port GGGVSpp sh r 1
1(a)
40960 40975 40977
none



15(b)
Any
Audits and Updates Test (#36)



18
0
busy station extension
WRN
ON
release station extension
130(c)

None
WRN
ON
test port GGGVSpp sh
257(d)
40973
none



513(e)

Station Present Test (#48)
WRN
OFF
test port GGGVSpp sh r 2
769

Battery Feed Test (#35)
MIN/ WRN**
ON
test port GGGVSpp sh r 2
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test description and follow the recommended procedures.
**Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options command.

Notes:


Previous page Next page