Port Audit Update Test (#36)

This test will send updates of the CO port translation for all ports on the Media Module which have been translated. The update is non-disruptive and guards against possible corruption of translation data contained on the Media Module. No response message is expected from the Media Module once it receives translation updates. The port translation data includes: ground or loop start trunk, tone or rotary dialing trunk, rotary dialing inter-digit timing, network balance R/RC, and disconnect timing.

Table 7. TEST #36 Port Audit Update Test �
Error Code
Test Result
Description/ Recommendation

ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
1006
ABORT
The port has been placed out of service, perhaps by craft busyout.
Use the display port GGGVSpp command to determine the trunk group/member number of the port. Use the status trunk command to determine the service state of the port. If the service state indicates that the port is in use, wait until the port is idle before testing.
If the port status is idle, retry the command at 1-minute intervals for a maximum of 5 times.
2100
ABORT
System resources required to run this test were not available.
If the port status is idle, retry the command at 1-minute intervals for a maximum of 5 times.

FAIL
Internal system error
Retry the command at 1-minute intervals for a maximum of 5 times.

PASS
This test passed. Translation information was successfully updated on the Media Module. User-reported troubles on this port should be investigated by using other port tests and by examining trunk or external wiring. If the trunk is busied out, the test will not run, but will return PASS. To verify that the trunk is in-service:
Enter status trunk to verify that the trunk is in-service. If the trunk is in-service, no further action is necessary. If the trunk is out-of-service, continue to Step 2.
Enter release trunk command to put trunk back into in-service.
Retry the test command.
Any
NO BOARD
The test could not relate the internal ID to the port (no board).
Check to ensure that the board translations are correct. Translate the board, if necessary.
Issue the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board command. This should re-establish the linkage between the internal ID and the port.