Error Log Entries and Test to Clear Values

Table 9. DID-DS1 Trunk Error Log Entries
Error Type
Aux Data
Associated Test
Alarm Level
On/Off Board
Test to Clear Value
0*
0
Any
Any
Any
test trunk grp#/mbr#
1(a)
Any




15(b)
Any
Port Audit and Update Test (#36)



18(c)


WARNING
OFF
release trunk grp#/mbr#
130(d)

None
WARNING
ON
test trunk grp#/mbr#
257(e)
57474 57473




513(f)
57392

MIN/MAJ**


769(g)
57393

MIN/MAJ**


1793(h)




test board GGGVSpp
2305(i)
50944
None
MIN/MAJ**
OFF

3840(j)

Port Audit and Update Test (#36)



*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test description and follow the recommended procedures.
**This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are out of service, then the alarm will be upgraded to a MAJOR alarm.
***Major alarms may be downgraded to Warning alarms based on the value used in the set options command.