Signaling Link Board Check (#643)

This test checks the health of the MM710 Interface transporting the ISDN-PRI Signaling Link Port

Table 33. Test #643 Signaling Link Board Check �
Error Code
Test Result
Description/ Recommendation

ABORT
Internal System Error
Retry the command at 1-minute intervals for a maximum of 5 times.
If the test continues to abort, escalate the problem.
1700
ABORT
Rollabout video abort. The PRI terminal adapter associated with this D-channel port is detached from the Media Module. This is normal when the rollabout video feature is enabled. To complete a test on this port, do one of the following:
Re-attach the disconnected PRI terminal adapter
Disable the rollabout video feature on this board by entering change ds1 GGGVSpp and set the field labeled "Alarm when PRI Endpoint Detached?" to "y."
8
FAIL
The MM710 is not in-service.
Check the Hardware Error Log for entries logged against DS1 MM and consult the DS1 Interface Media Module Maintenance documentation for repair procedures.

PASS
The MM-DS1 Interface Media Module transporting the ISDN-PRI Signaling Link Port is in-service.
Any
NO BOARD
The test could not relate the internal ID to the port (no board). This could be due to incorrect translations, no board is inserted, an incorrect board is inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the add ds1 GGGVS command to administer the DS1-MM interface if it is not already administered.
If the board was already administered correctly, check the error log to determine whether the board is hyperactive. If this is the case, the board is shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then issue the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.