Previous page Next page

Primary Signaling Link Hardware Check (#636)

The ISDN-PRI Signaling Group D-Channel port depends on the health of the Media Module on which it resides. This test will fail if there are problems with either the ISDN-PRI Primary D-channel port or the MM-DS1 Media Module. If there are problems with the ISDN-PRI Primary Signaling Channel port (ISDN-LNK), also investigate the Media Module.

Table 38. Primary Signaling Link Hardware Check (#636) �
Error Code
Test Result
Description/ Recommendation

ABORT
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
1700
ABORT
Rollabout video abort. The PRI terminal adapter associated with the primary D-channel port is detached from the Media Module. This is a normal abort when the rollabout video feature is enabled. To complete test on this port, either:
Re-attach the disconnected PRI terminal adapter, or
Disable the rollabout video feature on this board by entering change ds1 GGGVSpp and set field "Alarm when PRI Endpoint Detached?" to "y."
8
FAIL
There is a problem with the MM710 or the ISDN-PRI Signaling Channel (D-Channel). No ISDN trunk or PRI endpoint calls can be made until the problem is resolved.
Consult the procedures for the MM710 and the ISDN-PRI Signaling Channel (ISDN-LNK).

PASS
The basic physical connectivity of the primary D-channel is intact and functional. One might try this test repeatedly to ensure the link is up and to uncover any transitory problems.
Any
NO BOARD
The test could not relate the internal ID to the port (no board). This could be due to incorrect translations, no board is inserted, an incorrect board is inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the add ds1 GGGVS command to administer the DS1-MM interface if it is not already administered.
If the board was already administered correctly, check the error log to determine whether the board is hyperactive. If this is the case, the board is shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then issue the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.


Previous page Next page