Previous page Next page

MG-DCP (Digital Line Media Module)

DIG-LINE maintenance monitors and tests ports on digital line Media Modules and the hardware connected to those ports for lines administered as a digital station. Media Gateway-level maintenance is covered by "MG-DCP" whose strategy is described in the "XXX-BD (Common Port Media Module)" section.

Table 59. MG-DCP (MM712 Digital Line Media Module)
MO Name (in Alarm Log)
Alarm Level
Initial Command to Run*
Full Name of MO
MG-DCP
MIN
test board GGGVS sh
Digital Line Media Module
MG-DCP
WRN
test board GGGVS sh
Digital Line Media Module
Note: You must consult local records for the location and designation of the equipment rack where the G700 is mounted.

Note: Refer to XXX-BD (Common Port Media Module) for Media Module level errors. See also "DIG-LINE" for related line information.