Test Terminating Trunk Transmission ��

The Terminating Trunk Transmission Test provides for extension number access to 3 tone sequences that can be used for trunk transmission testing from the distant end of the trunks.

  1. Type change system-parameters maintenance and press Enter and go to screen 2.
  2. Under TERMINATING TRUNK TRANSMISSION TEST ( Extension ), type in 3 extension numbers in the 3 fields provided:
  3. Test Type 100:_______ Test Type 102:_______ Test Type 105:_______

Test Type
Test Features
Test type 100
5.5 seconds of 1004 Hz tone at 0 dB
Quiet until disconnect; disconnect is forced after 1 minute
Test Type 102
9 seconds of 1004 Hz tone at 0 dB
1 second of silence
Cycle is repeated until disconnect, which is forced after 24 hours
Test Type 105
9 seconds of 1004 Hz tone at -16 dB
1 second of silence
9 seconds of 404 Hz tone at -16 dB
1 second of silence
9 seconds of 2804 Hz tone at -16 dB
30 seconds of silence
0.5 seconds of test progress tone (2225 Hz)
About 5 seconds of silence
Forced disconnect