Previous page Next page

Alarming on the Avaya S8300 Media Server

S8300 alarms can be tested and corrected using SAT commands or the Web interface. If you run the Communication Manager application either from a telnet session (SAT window) or Avaya Site Administration, you can use the following SAT commands to obtain more information.

To Obtain Information from Communication Manager Alarms

Begin _____________________

  1. Use display alarms command:

Issuing the display alarms command at the administration terminal shows where maintenance software has logged alarms. The alarms are a good indication of the cause of system problems. They should be used in combination with the following.

  1. Observe RED LEDs on the Media Modules to determine if software or firmware had a problem.
  2. Use the reset command.

End _______________________

Clear Communication Manager alarms with various SAT commands and corrective actions documented in "Maintenance for Avaya DEFINITY� Server R, 555-233-117".

CAUTION: Only trained Avaya technicians should clear alarms.


Previous page Next page