Misframe Alarm indicates that framing bits observed on a MG-DS1 Interface Media Module are in error. The Misframe Alarm Inquiry Test queries the total number of misframes that have occurred on a DS1 Interface Media Module since the last inquiry.
When the DS1 Interface Media Module detects a misframe error, it increments its misframe counter by one. If the counter reaches a specified threshold (i.e., 17), a MISFRAME-COUNT message is automatically sent to the switch maintenance software. After the maintenance software receives the MISFRAME-COUNT message, the Misframe Alarm Inquiry Test is initiated to collect the misframe counts from the MG-DS1 Interface Media Module.
A Minor alarm against the MG-DS1 Interface Media Module is raised, but all trunks or ports of the MG-DS1 Interface Media Module remain in the in-service state.
|
|
|