Table 169. DS1 Tie Trunk Maintenance Error Log Entries
| Error Type |
Aux Data |
Associated Test |
Alarm Level |
On/Off Board |
Test to Clear Value |
| 0* |
0 |
Any |
Any |
Any |
test trunk grp/mbr |
| 1(a) |
57476 57477 57485 57487 |
|
|
|
|
| 15(b) |
Any |
Port Audit and Update Test (#36) |
|
|
|
| 18(c) |
0 |
busyout trunk grp/mbr |
WARNING |
OFF |
release trunk grp/mbr* |
| 19(d) |
0 |
None |
|
|
|
| 130(e) |
|
None |
WARNING |
ON |
test trunk grp/mbr |
| 257(f) |
57473 57474 |
|
|
|
|
| 513(g) |
57392 |
DS1 Tie Trunk Seizure Test (#136) |
MIN/MAJ |
|
|
| 769(h) |
57393 |
DS1 Tie Trunk Seizure Test (#136) |
MIN/MAJ |
|
|
| 1025 |
|
DS1 Tie Trunk Seizure (Test #136) |
MIN/ WRN*** |
OFF |
test trunk grp/mbr r 2 |
| 1793(i) |
|
|
|
|
test board GGGVSpp long |
| 2305(j) |
50944 |
DS1 Tie Trunk Seizure Test (#136) |
MIN/MAJ |
OFF |
|
| 2562(k) |
16665 |
|
|
|
|
| 2817(l) |
52992 |
|
|
|
|
| 3840(m) |
Any |
Port Audit and Update (Test #36) |
|
|
|
| *Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test description and follow the recommended procedures. |
| ***This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are out of service, then the alarm will be upgraded to a MAJOR alarm. |
| ****Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options command. |
| � |