Table 96. DID-DS1 Trunk Error Log Entries
| Error Type |
Aux Data |
Associated Test |
Alarm Level |
On/Off Board |
Test to Clear Value |
| 0* |
0 |
Any |
Any |
Any |
test trunk grp#/mbr# |
| 1(a) |
Any |
|
|
|
|
| 15(b) |
Any |
Port Audit and Update Test (#36) |
|
|
|
| 18(c) |
|
|
WARNING |
OFF |
release trunk grp#/mbr# |
| 130(d) |
|
None |
WARNING |
ON |
test trunk grp#/mbr# |
| 257(e) |
57474 57473 |
|
|
|
|
| 513(f) |
57392 |
|
MIN/MAJ** |
|
|
| 769(g) |
57393 |
|
MIN/MAJ** |
|
|
| 1793(h) |
|
|
|
|
test board GGGVSpp |
| 2305(i) |
50944 |
None |
MIN/MAJ** |
OFF |
|
| 3840(j) |
|
Port Audit and Update Test (#36) |
|
|
|
| *Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test description and follow the recommended procedures. |
| **This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are out of service, then the alarm will be upgraded to a MAJOR alarm. |
| ***Major alarms may be downgraded to Warning alarms based on the value used in the set options command. |