Previous page Next page

System Technician-Demanded Tests: Descriptions and Error Codes

CAUTION:


Always investigate tests in the order they are presented in the table below when inspecting errors in the system. By clearing error codes associated with the NPE Crosstalk Test, for example, you may also clear errors generated from other tests in the testing sequence.
Table 142. Order of Investigation
Order of Investigation
Short Test Sequence
Long Test Sequence
Reset Board Sequence
D/ND*
NPE Audit Test (#50)
Note: This test will abort with Error Code 1412.

X

ND
Ringing Application Test (#51)
Aborts with code 1412




Control Channel Looparound Test (#52)
X
X

ND
SAKI Sanity Test (#53)

X
D

NEON Test (#220)
Aborts with code 1412




*D = Destructive; ND = Nondestructive

For hardware error log entries and for more information on the tests listed in the table above refer to "MO XXX-BD (common port Media Module)" maintenance object documentation.