SWASR009
Alarm level
Major
Description
The channel is outside the range of administered channels.  
Repair procedure
To correct the problem:
- Go to the Display Equipment screen (Configuration Management > Voice Equipment > Display Equipment) to check the administration of the channel. 
 - If the channel is configured incorrectly, assign the appropriate services to the channel. 
See Channel services for more information. 
 - If the channel is configured correctly, go to the Feature Licensing screen (Configuration Management > Feature Licensing) and to check the number of Right-To-Use (RTU) licenses available.  
The number of channels should not exceed the number of licenses.
 - If the number of licenses is exceeded, contact your field support representative about purchasing more licenses.