Previous page Next page

alarm-relative disable

Disables generation of relative alarms.

Syntax

alarm-relative disable

no alarm-relative disable

Prerequisites

Must be in Chatter Configuration command mode.For information on how to access this mode, see Accessing and exiting command modes.

Occurrence

Use once.

Default

Enabled.

Description

Disables generation of relative alarms.

Relative alarms are generated when the most recent results for a specific test show an abrupt increase or decrease. The thresholds for determining an “abrupt increase or decrease” are self-adjusting thresholds based on a statistical technique. Note that if the measurement remains near or outside the threshold, the threshold adjusts to reflect this changed norm. Once the threshold self-adjusts, the alarm clears even though the measurement itself has not changed. The steady state becomes the threshold value - this value can be higher or lower than configured threshold. Relative alarms are forwarded as SNMP traps and to Syslog servers if configured to do so.

The no command restores the default setting of enabled.


Previous page Next page