Previous page Next page

alarm-relative disable traceroute

Disables relative alarms for Traceroute tests on any cell or edge that is assigned this alarm template.

You can control the generation of relative alarms for each measurement variable individually or all measurements collectively.

Syntax

alarm-relative disable traceroute (all | hop-rtt | inter-arrival-time)

no alarm-relative disable traceroute

no alarm-relative disable traceroute (all | hop-rtt | inter-arrival-time)

Arguments
Table 13:  alarm-relative disable traceroute arguments  
Argument
Description
all

Disables relative alarms for all Traceroute measurements: hop-rtt and inter-arrival-time.

hop-rtt <milliseconds>

Disables relative alarms for Traceroute hop round trip time (RTT).

Hop RTT is the round trip time for each hop along the route (UDP outbound and ICMP inbound).

inter-arrival-time <milliseconds>

Disables relative alarms for Traceroute inter-arrival-time.

Inter arrival time is the time between tests, and can be used to trigger an alarm when a link is down or a set of endpoints becomes isolated.

Prerequisites

Must be in Chatter Alarm Configuration mode. For information on how to access this mode, see Accessing and exiting command modes.

Occurrence

Available for use multiple times in the configuration.

Default

Relative alarms are enabled for all TCP measurements.

Description

Disables relative alarms for Traceroute tests on any cell or edge that is assigned this alarm template.

You can control the generation of relative alarms for each measurement variable individually or all measurements collectively.

The no command restores the default value of enabled for all Traceroute measurements or the specified measurement variable.


Previous page Next page