Previous page Next page

outage-detection active-probe

Defines the number of consecutive active-probe failures that should be interpreted by the CNA decision-maker process as an outage for the prefix.

Syntax
outage-detection active-probe { enable | disable |
 
       failure-threshold <fail-num> | measurement-threshold <meas-num> }
 
no outage-detection active-probe { enable | disable |
 
       failure-threshold | measurement-threshold }
 
Arguments
Prerequisites

Must be in engine or decision policy configuration mode (config-engine or config-engine-policy), which requires privileged-level access.

Occurrence

Use once globally, and once per decision policy.

Description

Use the outage-detection active-probe command to define an outage as measured by active probing.

If an active probe fails fail-num consecutive times over the same link, an outage will be declared for the targeted prefix over that link. (Failure means no response from the target for a length of time specified as the timeout value in the active probe configuration.)

The current value of num is displayed as probe-failure-threshold in the output generated by the show statistics command with dmaker as the argument.

The outage will be considered to have ended after meas-num active probe successes for that prefix over the same link.

Use the no form of the command to revert to the defaults, either globally or within a decision policy.