polling interface-description (deprecated)

NOTE: See the new command: polling interface.Tells CNA which interface to poll, using the ifDescr MIB variable as the key.

Syntax
polling interface-description <text>
 
no polling interface-description 
 
Arguments

text--value of the interface’s ifDescr MIB variable on the router (maximum length: 255 characters).

Prerequisites

Must be in link configuration mode (config-engine-link), which requires privileged-level access.

Occurrence

Use once per link.

Description

When polling for usage data, CNA needs to know where to look. The device will use whichever of the following you have set (use only one in the CNA configuration):

Use the no form of the command to clear the association between the link and an SNMP configuration block.