Displays or sets the system time.
time [<value>]
System operations mode; requires login-level access to display, privileged-level access to set.
All peripheral modules in CNA take their NTP feed from the Management Processor module.
There must always be six digits in value. Do not use colons, but do use leading zeros for single-digit hours, minutes or seconds.
You cannot reset the time while NTP is enabled.
Resetting the system time to an earlier date/time may result in a gap in your snapshot reports as well as polling by the link-monitor process.
The snapshot reports problem is self-correcting; snapshots will resume when the system time and the snapshot schedule become synchronized again.
In order to resume polling immediately, you should restart the link-monitor process, using the medic call command.
CNA must be restarted before time changes will be implemented by some database-related CNA processes.
Changing the system time while active probes are enabled can disrupt active probing. See Troubleshooting Agent-Based Measurement in Chapter 4: Server-Based Measurement of the CNA Basic Monitoring Guide.
|
|
|