DEFINITY Made Easy Tools
Issue 3, December 2001
Add IP Solutions
Test the External Connection to the LAN
To test the external IP connections, ping the C-LAN or IP Media Processor server and ping a known computer connected to your network. If everything is configured correctly, the Result column on the Ping Results screen reads pass. If it reads abort, verify the IP-address information and check the connectivity, including the cabling.
- Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and press Enter . The variable nnn.nnn.nnn.nnn is the IP address of the IP Media Processor and UUCSS is the cabinet, carrier, and slot of the IP Media Processor.
- Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and press Enter . The variable nnn.nnn.nnn.nnn is the IP address of the customer's gateway and UUCSS is the cabinet, carrier, and slot of the IP Media Processor.
- Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and press Enter . The variable nnn.nnn.nnn.nnn is the IP address of another computer beyond the gateway and UUCSS is the cabinet, carrier, and slot of the TN2302AP IP Media Processor.
The IP Media Processor is now installed in the DEFINITY carrier and connected to the IP network.
Ping Results screen