Save Translations for R10si
Return to Task List
This command copies the current system translations onto the translation card or removable media. For standard reliability systems, one translation card plus one backup is required. For high or critical reliability systems, two translation cards plus two backups are required.
The following procedure can be used to save system translations on the original card(s) and can also can be used to make a backup card or cards:
- Type
save translation and press
Enter.
- Verify a
0 is displayed in the
Error Code column for each Switch Processing Element (SPE). A
0 indicates the save translation was successfully completed. If a
0 did not appear, the save translation did not complete. Record the error code number and the error message and notify your Avaya representative.
- Remove the original translation card from the processor circuit pack and replace it with the backup card.
- Repeat steps 1 through 4 for the backup card.
- Remove the backup translation card from the processor circuit pack and replace it with the original translation card.
- Label the backup card with the date and time of the backup. Store the backup card in a secure place.
- Repeat this process for high or critical reliability systems.
Return to Task List