DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC



Save Translations (DS1 Tie and OPS Trunks)

Return to Task List

  1. If the system is high or critical reliability, type status system 1 and press Enter to verify that the system is in the "active/standby" mode.

  2. Type save translation and press Enter. This instructs the system to take all translation information in memory and write it to the translation card or removable media.

  3. If the system contains a TN750/B Announcement circuit pack, type display announcements and press Enter. If administered recorded announcements are listed, type list configuration software-version press Enter. Check Page 2 of this form to see when the announcements were last saved. To save the current announcements, type save announcements and press Enter.