DEFINITY Made Easy Tools
Issue 3, December 2001
Test the System
Test Tone-Clock Interchange for Each Expansion Port Network
If the system is critical reliability, test the Tone-Clock interchange for each Expansion Port Network (EPN).
- If Multi-Carrier Cabinet, type
status system
cabinet number <1-44>
and press
Enter.
or
If Single-Carrier Cabinet, type status system all-cabinets and press Enter. - Type set tone-clock xx where xx is the Port-Network/Carrier for the Standby Tone-Clock. Press Enter.
- If Multi-Carrier Cabinet, type
status system
cabinet number <1-44>
and press
Enter.
or
If Single-Carrier Cabinet, type status system all-cabinets and press Enter. - Verify the duplicated Tone-Clock is active using the information displayed on the screen.
This displays the location of the Standby Tone-Clock.
If any problems are indicated, check the TDM cables in the associated Expansion Port Network (EPN).
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Copyright� 2001 Avaya Inc. |
Send comments to MadeEasy Development Team |