This topic provides information you can use to troubleshoot the INTUITY LX 1000 platform, including the serial modem, voice ports, keyboard, and modem.

The Serial Modem Does Not Answer


 
Possible Cause
Action
Probable Fix
There is no power to the modem.
Check the power source.
Apply power to the modem.
The modem is not connected.
Verify that the modem is connected properly.
Connect the modem correctly.

The Voice Ports Are Answering in Standalone Mode


 
Possible Cause
Action
Probable Fix
The voice port administration does not match the extension numbers attached to the ports.
Verify that the voice port administration matches the extensions to which the voice ports are attached.
Change the voice port assignment to match the extensions to which the ports are connected.
The link to the switch is out of service.
Check the link to the switch.
Subscribers have the wrong PBX assigned.
Verify that the correct PBX is entered in the Switch Number field on page 1 of the Subscriber screen.

Assign the correct switch in the subscriber profile.

Verify that the assigned switch is defined correctly in the system's switch administration.

Cannot Assign Voice Ports


 
Possible Cause
Action
Probable Fix
Additional port activation has not been purchased by the customer.
Verify the number of ports purchased by the customer. Access Global Administration > Customer Options from the main Administration menu. Check the number of voice ports listed.
Contact sales personnel.

The Keyboard Is Not Operating


 
Possible Cause
Action
Probable Fix
The keyboard is not plugged in properly.
Check the keyboard connection.
Disconnect and reconnect the keyboard.
The keyboard is "frozen."
Check the keyboard connection.

The Monitor Is Not Operating


 
Possible Cause
Action
Probable Fix
The monitor has not been turned on.
Check the monitor switch.
Turn on the monitor.
The monitor brightness has been turned down.
Check the monitor brightness knob.
Turn up the brightness.

The Analog-line Interface Card Is Not Recognized by the INTUITY AUDIX System


 
Possible Cause
Action
Probable Fix
The cards are incorrectly numbered.
There is nothing to check in this instance. If this is the suspected problem, continue with the probable fix.

Check the board IDs of the installed cards. To this, you must get inside the platform.

Analog-line interface cards are placed in the slots numbered PCI 3 through PCI 1, from bottom to top. Board IDs assignment are as follows: the card in PCI slot 3 is assigned ID 0;
the card in PCI slot 2 is assigned ID 1; and the card in PCI slot 1 is assigned ID 2.

If necessary, change the board IDs of the incorrect cards and then replace the PC cover and restore power.

A card is not properly seated in the slot. Follow the procedures to get inside the PC and verify that the card is properly seated in the slot. If the card is not properly seated, correct the seating of the card and then follow the procedures to return power and replace the PC cover.