Removing Power from the MAP/40P
The MAP/40P requires a dedicated circuit with a dedicated circuit breaker. The power cord connects to the rear of the MAP/40P at the point labeled AC input receptacle. See the Back View of the MAP/40P. Before you begin any work in the MAP/40P you must disconnect the incoming power.
- Shut down the system.
- Turn off the monitor's power switch.
The green or amber lamp on the front bottom of the monitor should be off.
- Turn off the power switch on the front of the MAP/40P.
The green lamp, labeled POWER ON, on the front of the unit should be off.
- Unplug the MAP/40P from the power outlet.
- Remove the MAP/40P power cord from the AC input receptacle on the rear of the MAP/40P.
Removing the Dress Cover
The dress cover provides protection for the internal components of the MAP/40P. You must remove the dress cover to access these components. See the Back View of the MAP/40P.
Shut power off before removing the dress cover or access panel of the MAP/40P.
- Ensure that the MAP/40P tower configuration is in an upright position on the support base.
- Remove the six screws located along the bottom of the MAP/40P.
There are three screws on each side of the MAP/40P.
- Remove the screw holding the dress cover to the rear of the MAP/40P.
- Remove the front bezel by pulling it forward.
- At the rear of the MAP/40P, pry both sides of the dress cover away from the unit.
As more of the dress cover is removed, it may begin to collapse inward from the pressure.- Slide the dress cover up and then forward to remove it from the MAP/40P.
Replacing the Dress Cover
- Slide the dress cover into position.
Note: Be careful not to catch any cables in the dress cover.
- Replace the screw holding the dress cover to the rear of the MAP/40P.
- Replace the six screws along the sides of the MAP/40P.
Restoring Power to the MAP/40P
The MAP/40P requires a dedicated power line.The power cord connects to the rear of the MAP/40P at the point labeled input receptacle. See the Back View of the MAP/40P.
To restore power to the MAP/40P:
- Place the MAP/40P power cord in the AC input receptacle on the rear of the unit.
- Plug the MAP/40P power cord into the designated power outlet.
- Turn on the power switch on the front of the MAP/40P.
The green lamp, labeled POWER ON, on the front of the unit should be lit.
- Turn on the monitor's power switch.
The green or amber lamp on the front bottom of the monitor should be lit.
![]() http://www.avaya.com Avaya UCS Information Development |
![]() |
![]() |
![]() |