Busying Out the Switch Data Link
Important! This task applies only to DEFINITY switches. If the customer does not have a DEFINITY switch, do not use this task and go to the next task in the procedure.
When the voice system is turned off for an upgrade, DEFINITY switches activate an alarm. Busying out the link between the voice system and switch prevents alarms from being sent to the remote support center. Choose one of the following procedures based on the type of DEFINITY switch:
- Busying Out the Data Link on a System 75 G1 or G3 Switch
- Busying Out the Data Link on a G2 Switch
- Busying Out the Data Link in an OverLAN Integration
Busying Out the Data Link on a System 75 G1 or G3 Switch
To busy out the data link on a System 75 G1 or G3 switch, perform the following tasks on the switch administration terminal (SAT):
- Enter busy link n
where n is the number of the link going to the Avaya Intuity system. Valid input is an integer from 1 to 8.
For more information, see the DEFINITY switch documentation.
- Continue with the next task.
Busying Out the Data Link on a G2 Switch
To busy out the data link on a G2 switch, perform the following tasks on the switch administration terminal (SAT):
- Enter proc650 test 3
- Enter the Intuity AUDIX link number in field 6.
- Enter bu bu
For more information, see the DEFINITY switch documentation.
- Continue with the next task.
Busying Out the Data Link in an OverLAN Integration
To busy out the data link in an OverLAN integration, perform the following tasks on the switch administration terminal (SAT):