ASAI002 (A_LINKDWN_LL)

Alarm level

Critical.

Description

The ASAI physical link is up, but the ASAI environment cannot be set. All ASAI-provided services will not function until the link has been re-established.

Note:
If message ASAI025 follows this message, no corrective action is necessary.

Repair procedure:

To correct the problem and remove the alarm:

  1. Contact your remote maintenance service center for assistance.
  2. Check with your PBX administrator to ensure that the ASAI port on the PBX has been administered with Fixed TEI=y and TEI=3.
  3. Go to the ASAI Parameters screen (Feature Packages > ASAI Administration > Parameters) and make sure that the:
  4. Make sure that another Avaya IR system is not using the same NODE_ID.

See Also

ASAI administration screens