Use this screen to change the values of the dialout parameters.
Field descriptions
Field |
Description |
Product ID |
The INADS product ID. Values: A 10-digit number. The default is 4000000000. This field is automatically updated when the product is registered with INADS. |
Trace on? |
The state of the trace function. Values: enabled=yes, disabled=no. |
Dialout on? |
The state of the dialout function. Values: enabled=yes, disabled=no. |
Maximum Allowable Temperature |
The temperature, in degrees Celsius, above which the system calls a dialout location. Values: Integer. Example: 45. |
Minor Alarms Tracked? |
The tracking of minor alarms. Values: no, yes. |
Port Used |
The port used when dialing out. Values: ttya, ttyb |
Location ID |
The name of the location that the system calls. Values: Any string. |
Phone Number |
The telephone number that the system calls. Values: Allowable characters are: 0-9, (, ), #, *, ., [blank],-. Example: (303)555-5555 |
Modem Speed |
The baud rate of the modem. Values: 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 76800, 115200, 153600, 230400, 307200, 460800. |
Char Size |
The number of bits in a character. Values: 7, 8. |
Parity |
The parity of the modem. Values: even, odd, none. |
Dialstring |
The dialstring to use when using the modem. Values: A string of standard Hayes AT modem commands, which include the following:
Example: \date0q0\n\r OK\r atdt\T\n\r CONNECT\s \d\d\I so\s2 Default dialstrings are to INADS for Dialout Location 1, and to a pager for Dialout Location 2. |
Button descriptions
Button |
Description |
Submit |
Changes the dialout parameters |
Reset |
Sets fields to their default values |
Cancel |
Displays the Dialout Configuration screen |
Administration procedures