If you detect failure in disk drive on a mirrored system, you must remove and replace it with a good one.
To remove a failed hard disk drive:
stop_vs
.The voice system stops.
mirror_admin detach.
The system displays the following prompt:
Prompt for hard disk drive to detach
The system detaches all submirrors from the failed hard disk drive.
For information on how to remove a disk drive, see the Sun Fire V210 and V240 Servers Parts Replacement Manual or the Sun Fire 280R Server Service Manual.