Clock Synchronization |
|
Programmable by
|
System Manager
|
Mode
|
All
|
Idle Condition
|
Not required
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity 100D, 100R INA, and
100 DCD module
3i, Incoming Trunks: BRI Options
|
Factory Setting
|
Primary clock: the first 100D/100R module in the control unit
carrier
|
Valid Entries
|
Primary, Secondary, Tertiary, Loop/Local |
Inspect
|
No |
Copy Option
|
No
|
Console Procedure
|
Specify modules that provide primary, secondary, and tertiary clock synchronization
and source of clock synchronization; also activate/deactivate clock:
LinesTrunks More ClockSync
Primary 
Dial slot no. (1-17) Enter
Dial port no. or select source of synchronization Enter
Secondary Dial slot no.
(1-17) Enter Dial port
no. or select source of synchronization Enter
Tertiary Dial slot no.
(1-17) Enter Dial port
no. or select source of synchronization Enter
Back Back
|
DS1 Facilities
|
|
Type of DS1 Facility
|
|
Programmable by
|
System Manager
|
Mode
|
All
|
Idle Condition
|
100R module idle
|
Planning Form
|
2c, System Numbering: Line/Trunk Jacks
3b, Incoming Trunks: DS1 Connectivity (100D, 100R INA, and
100 DCD module)
|
Factory Setting
|
T1, See Switched 56 Data Signaling Options.
|
Valid Entries
|
T1, PRI |
Inspect
|
Yes |
Copy Option
|
No
|
Procedure
|
Specify type of facility connected to 100D, 100R INA, or 100 DCD module:
To select PRI:
LinesTrunks
LS/GS/DS1 Dial slot no. (1-17) Enter

Type PRI Enter Back Back Back
Back
To select T1 All Ground, All Loop, or All Unequip:
LinesTrunks
LS/GS/DS1 Dial slot no. (1-17) Enter
Type T1 Enter
Select type of emulation Enter

Back Back Back Back
To select T1 Ground-Start, Loop-Start, All Tie, or Unequip:
LinesTrunks
LS/GS/DS1 Dial slot no. (1-17) Enter

Type T1 Enter Select type of emulation
Enter 
Dial channel no. Enter
Back Back Back Back
To select T1 All DID:
LinesTrunks
LS/GS/DS1 Dial slot no. (1-17) Enter

Type T1 Enter
or More All
DID Enter 
Back Back Back Back
To select T1 DID:
LinesTrunks
LS/GS/DS1 Dial slot no. (1-17) Enter

Type T1 Enter
or More DID
Enter Dial channel no. Enter
Back Back Back
Back
To select T1 All Tie:
LinesTrunks
LS/GS/DS1 Dial slot no. (1-17) Enter

Type T1 Enter All TIE Enter 
TIE-PBX, Toll, or S56
Enter Dial channel no. 
Enter Back
Back Back Back
To select T1 Tie:
LinesTrunks
LS/GS/DS1 Dial slot no. (1-17) Enter

Type T1 Enter TIE Enter TIE-PBX,
Toll, or S56
Enter Dial channel no. Enter
Back Back 
Back Back
To select T1 All Switched 56 Data:
LinesTrunks
LS/GS/DS1 Dial slot no. (1-17) Enter

Type T1 Enter
or More ALL
S56 Data Enter 
Select Direction , Intype , Outtype , AnsSupv
, Disconnect , Inmode , or Outmode
Program options Enter Back

Back Back Back
To select T1 Switched 56 Data and program Channel Signaling:
LinesTrunks
LS/GS/DS1 Dial slot no. (1-17) Enter
Type T1 Enter
or More S56
Data Enter 
Dial channel no. Enter
Select Direction , Intype , Outtype , AnsSupv
, Disconnect , Inmode , or Outmode
Program options Enter 
Back Back Back Back
|
Switched 56 Data Signaling Options
|
Option
|
Factory Setting
|
Range
|
Direction
|
Two-Way
|
Two-Way, Outgoing, Incoming
|
Intype
|
Wink-Route by
Dial Plant
|
Wink-Route by Dial Plan,
Delay-Route by Dial Plan
Auto-Route by Line Appearance
|
Outtype
|
Wink
|
Wink, Delay, Auto
|
Answer Supervision
|
300 ms
|
200-4,800 ms (increments of 20 ms)
|
Disconnect
|
300 ms
|
200-4,800 ms (increments of 20 ms)
|
Inmode
|
Touch Tone
|
Touch Tone, Rotary
|
Outmode
|
Touch Tone
|
Touch Tone, Rotary
|
|
Frame Format
|
|
Programmable by
|
System Manager
|
Mode
|
All
|
Idle Condition
|
100D module idle
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity (100D, 100R INA, and 100 DCD module)
|
Factory Setting
|
D4-compatible
|
Valid Entries
|
D4, ESF |
Inspect
|
No |
Copy Option
|
No
|
Procedure
|
Specify framing format for 100D, 100R INA, or 100 DCD module:
LinesTrunks
LS/GS/DS1 Dial slot no. (1-17) Enter

FrameFormat Select D4-Compatible
or Extended Superframe Enter Back Back
|
Zero Code Suppression
|
|
Programmable by
|
System Manager
|
Mode
|
All
|
Idle Condition
|
100D module idle
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity (100D, 100R INA, and 100 DCD module)
|
Factory Setting
|
AMI-ZCS
|
Valid Entries
|
AMI-ZCS, B8ZS |
Inspect
|
No |
Copy Option
|
No
|
Procedure
|
Specify line coding for 100D, 100R INA, or 100 DCD module:
LinesTrunks
LS/GS/DS1 Dial slot no. (1-17) Enter

Suppression AMI-ZCS or B8ZS
Enter Back Back
|
Line Compensation
|
|
Programmable by
|
System Manager
|
Mode
|
All
|
Idle Condition
|
100R module idle
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity (100D, 100R INA, and 100 DCD module)
|
Factory Setting
|
1 (0.6 dB loss)
|
Valid Entries
|
1 to 5 |
Inspect
|
No |
Copy Option
|
No
|
Procedure
|
Specify line compensation between 100D, 100R INA, or 100 DCD module and
channel service unit (CSU) or far end:
LinesTrunks
LS/GS/DS1 Dial slot no. (1-17) Enter

Line Comp Drop Dial line compensation value (1-5)
Enter 
Back Back
|
Channel Service Unit
|
|
Programmable by
|
System Manager
|
Mode
|
All
|
Idle Condition
|
100R INA and 100 DCD module idle
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity (100D, 100R INA, and 100 DCD module)
|
Factory Setting
|
Foreign Exchange
|
Valid Entries
|
Foreign Exchange, Special Access |
Inspect
|
No |
Copy Option
|
No
|
Procedure
|
Specify type of CSU equipment provided by central office:
LinesTrunks
LS/GS/DS1 Dial slot no. (1-17) Enter
ChannelUnit Foreign Exchange
or Special
Access 
Enter Back Back
|
PRI Facilities |
|
If you are adding PRI facilities to an existing system, certain
values must be set correctly. To inspect or change these values,
see. Do not start these procedures until you have checked the following:
- Type of DS1 Facility must be set to PRI.
- Frame format must be specified correctly.
- Zero code suppression must be specified correctly.
- Clock synchronization source must be set to loop (derived from
the T1 line).
|
The settings for frame format and zero code suppression must be consistent
with the options selected when the PRI connection was ordered.
If you are using ARS in connection with PRI, make sure you select voice,
data, or voice and data, as appropriate, when you perform the ARS "Voice
and/or Data Routing".
|
Switch Type |
|
Programmable by
|
System Manager
|
Mode
|
Hybrid/PBX
|
Idle Condition
|
Not required
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity (100D, 100R INA, and 100 DCD module)
|
Factory Setting
|
4ESS
|
Valid Entries
|
Not applicable |
Inspect
|
Yes |
Copy Option
|
No
|
Procedure
|
Specify the type of switch:
LinesTrunks
PRI SwitchType Dial slot no. (1-17)
Enter Specify switch type
Enter
Back Back
|
Telephone Number
|
|
Programmable by
|
System Manager
|
Mode
|
Hybrid/PBX, Key
|
Idle Condition
|
Not required
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity (100D, 100R INA, and 100D CD module)
|
Factory Setting
|
No digits
|
Valid Entries
|
Up to 12 digits (any combination of 0 to
9) |
Inspect
|
No |
Copy Option
|
No
|
Procedure
|
Assign telephone numbers to PRI lines:
LinesTrunks
PRI PhoneNumber Dial trunk no. Enter

Drop Dial telephone no. (up to 12 digits; 0-9)
Enter Back

Back
|
B-Channel Groups
|
|
Programmable by
|
System Manager
|
Mode
|
Hybrid/PBX, Key
|
Idle Condition
|
Not required
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity (100D, 100R INA, and 100 DCD module)
|
Factory Setting
|
Not applicable
|
Valid Entries
|
Group numbers (1 to 80) |
Inspect
|
Yes |
Copy Option
|
No
|
Procedure
|
Assign B-channels to group and assign PRI lines to B-channel groups:
To program a single-line/trunk:
LinesTrunks
PRI B-ChannlGrp B Channels 
Dial group no. (1-80) Enter
Dial B-channel slot and port nos. Enter
Lines Dial group no.
Enter
Entry Mode Dial line/trunk no. Enter
Back Back Back
To program a block of lines/trunks:
LinesTrunks
PRI B-ChannlGrp B Channels 
Dial group no. (1-80) Enter Dial B-channel slot and
port no. Enter
Lines Dial group no. Enter

Select specific lines/trunks Toggle LED On/Off 
Back Back
Back
|
Network Service
|
|
Programmable by
|
System Manager
|
Mode
|
Hybrid/PBX, Key
|
Idle Condition
|
Not required
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity (100D, 100R INA, and 100 DCD module)
|
Factory Setting
|
Not applicable
|
Valid Entries
|
AT&T Toll, 5ESS Local, MCI Toll, Miscellaneous,
DMS-100 Local, LEGEND UDP |
Inspect
|
Yes |
Copy Option
|
No
|
Procedure
|
Specify type of network service for each B-channel group:
LinesTrunks
PRI B-ChannlGrp NetworkServ 
Dial group no. Enter
Specify network service (AT&T Toll, 5ESS Local, MCI Toll, Miscellaneous,
DMS-100, Local, Legend UDP) Enter
Back Back Back
Back
|
Copy Telephone Number to Send
|
|
Programmable by
|
System Manager
|
Mode
|
Hybrid/PBX, Key
|
Idle Condition
|
Not required
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity (100D, 100R INA, and 100 DCD module)
|
Factory Setting
|
Do Not Copy
|
Valid Entries
|
Do Not Copy, Copy |
Inspect
|
No |
Copy Option
|
No
|
Procedure
|
Specify whether telephone number to send to network for outgoing calls
should be copied from line telephone number:
LinesTrunks
PRI B ChannlGrp Copy Number 
Dial group no. Enter
Specify copy or no copy Enter

Back Back Back
|
Telephone Number to Send
|
|
Programmable by
|
System Manager
|
Mode
|
All
|
Idle Condition
|
Not required
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity (100D, 100R INA, and 100 DCD module)
|
Factory Setting
|
No digits are assigned
|
Valid Entries
|
Up to 12 digits (any combination of 0 to
9) |
Inspect
|
No |
Copy Option
|
No
|
Procedure
|
Specify telephone number to send to network for outgoing calls on PRI
lines:
LinesTrunks
PRI NumbrToSend Specify type of no.
Enter Drop Dial base no.
Enter Dial line no.
Enter 
Drop Dial telephone no. (up to 12 digits; 0-9)
Enter Back

Back
|
Test Telephone Number
|
|
Programmable by
|
System Manager
|
Mode
|
Hybrid/PBX, Key
|
Idle Condition
|
Not required
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity (100D, 100R INA, and 100 DCD module)
|
Factory Setting
|
Not applicable
|
Valid Entries
|
Telephone number of up to 12 digits |
Inspect
|
No |
Copy Option
|
No
|
Procedure
|
Assign test line telephone number for each 100D, 100R INA, or 100 DCD
module:
LinesTrunks
PRI Test TelNum Dial slot no. (1-17)
Enter Drop Dial telephone
no. (up to 12 digits; 0-9) Enter

Back Back
|
Timers and Counters
|
|
Programmable by
|
System Manager
|
Mode
|
All
|
Idle Condition
|
Not required
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity (100D, 100R INA, and 100 DCD module)
|
Factory Setting
|
See the Table in the following
|
Valid Entries
|
See the Table in the following |
Inspect
|
No |
Copy Option
|
No
|
Procedure
|
Set timer and counter thresholds for each 100D, 100R INA, or 100 DCD
module:
LinesTrunks
PRI Protocol Timers 
Dial slot no. (1-17) Enter
Select timer/counter Drop 
Dial no. of ms/octets/and so on Enter
Back Back Back
Back
Timer/Counter
|
Purpose
|
Factory Setting
|
Valid Range
|
T200 Timer
|
Maximum response time
|
1 second
|
1,000 to 3,000 ms
|
T203 Timer
|
Maximum time
|
30 seconds
|
1 to 60 seconds
|
N200 Counter
|
Maximum transmissions
|
3 transmissions
|
1 to 5 transmissions
|
N201 Counter
|
Maximum octets
|
260 octets
|
16 to 260 octets
|
K Counter
|
Maximum outstanding
I-frames
|
7 frames
|
1 to 15 frames
|
T303 Timer
|
Set up timeout
|
4 seconds
|
4 to 12 seconds
|
T305 Timer
|
Disconnect timeout
|
4 seconds
|
4 to 30 seconds
|
T308 Timer
|
Release timeout
|
4 seconds
|
4 to 12 seconds
|
T309 Timer
|
Signal loss
|
90 seconds
|
30 to 120 seconds
|
T310 Timer
|
Call Proc. timeout
|
60 seconds
|
2 to 120 seconds
|
T313 Timer
|
Connect timeout
|
4 seconds
|
4 to 60 seconds
|
T316 Timer
|
Restart timeout
|
120 seconds
|
30 to 120 seconds
|
|
Terminal Equipment
Identifier |
|
Programmable by
|
System Manager
|
Mode
|
All
|
Idle Condition
|
Not required
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity (100D, 100R INA, and 100 DCD module)
|
Factory Setting
|
0
|
Valid Entries
|
0 to 63 |
Inspect
|
No |
Copy Option
|
No
|
Procedure
|
Assign link layer address or Terminal Equipment Identifier (TEI) of equipment
connected to each D-channel:
LinesTrunks
PRI Protocol TEI Dial slot no. (1-17)

Enter Drop Dial new ID
no. (0-63) Enter
Back Back 
Back
|
Switched 56 Dial
Plan Routing |
|
Programmable by
|
System Manager
|
Mode
|
Hybrid/PBX
|
Idle Condition
|
100R and 100 DCD modules idle
|
Planning Form
|
3b, Incoming Trunks: DS1 Connectivity (100D, 100R, and 100 DCD module)
|
Factory Setting
|
D4 compatible
|
Valid Entries
|
D4, ESF |
Inspect
|
No |
Copy Option
|
No
|
Procedure
|
To specify Expected Digits:
LinesTrunks
or More T1
Data NW S56 Dial Plan Routing Expected Digits
Drop Dial expected digits Enter Back Back
Back
To specify Delete Digits:
LinesTrunks
or More T1
Data NW S56 Dial Plan Routing Delete Digits Drop
Dial delete digits Enter
Back Back Back
To specify Add Digits:
LinesTrunks
or More
T1 Data NW
S56 Dial
Plan Routing
Add Digits
Drop
Dial add digits
Enter
Back Back
Back
|