If system attempts to make an alarm call repeatedly fail, the system
will stop attempting to report existing alarms, even if additional
alarms subsequently occur. The test alarm origination function will
also fail if the system is in this state.
Caution!
The problem that prevented the alarm calls from being
successfully completed must be resolved. If it is not, then
alarm origination will simply stop again after repeated call
attempts fail.
|
To allow the system to begin making calls about alarms again:
- Start at the Messaging Administration main
menu and select:
Basic System Administration
Alarming Administration
The system displays the Alarm Management page.
- Select Inactive from the Alarm Origination drop-down
list.
- Click Save.
- Now select Active from the Alarm Origination drop-down
list.
- Click Save.
Alarm origination is restored.
-
Click Return to Main to return to the Messaging Administration main
menu.
Top of page
|