MAS Alarm - VS FEDB 3

Level

Minor.

System Descriptor

FEDB resynchronization started. All Ports will be disabled.

Description

This alarm indicates that a full synchronization of the back end LDAP database with the front end database (FEDB) has been started. During a full synchronization, all necessary records from the LDAP store are copied to the FEDB (as opposed to normal operations in which only changed records are copied over).

While a full synchronization is in progress, all ports are disabled. When the synchronization has completed, the system again enables all ports.

Repair Procedure

There is no repair or recovery procedure for this alarm, as it is considered a notification only. When the synchronization is complete, the system automatically re-enables all applicable ports.